Wattwin
General

Solar panel datasheet: how to read it

Date Published

Photovoltaic solar panel datasheet: how to read it

Technical specifications are an important part of any electrical device, and solar panels are no exception. Reading and interpreting the parameters on these datasheets can be a little confusing, so in this article we explain everything you need to understand a solar panel datasheet.

Where to find the solar panel datasheet.

There are several reasons why it is important to be able to identify a photovoltaic panel's technical characteristics: to know whether it fits the technical needs of an installation, whether it is compatible with the other elements, with the electricity grid, etc. It is also important to check, for example, that the panels you bought and received have the technical characteristics you actually ordered. All this information is set out in the solar panel datasheet. You can find it in paper format with the panel, as a PDF on the website of the panel manufacturer or seller and, most importantly, on the back of the panel itself.

Datasheet: what information does it contain?

The information on the label may vary slightly from one manufacturer to another, but all of them include the most important technical parameters, which we explain here:

Maximum power or Pmax.

It is one of the most important parameters of solar panels, as it indicates the maximum power it can deliver in operation. Remember that it is always calculated under controlled laboratory conditions, so in reality it will be slightly lower depending on weather conditions. Panels are classified by this measurement in watts, for example “400 W solar panels”. Maximum power can also be obtained by multiplying Vmp by Imp.

Open circuit voltage or Voc.

This is the voltage the panel can supply when disconnected. In other words, it is the panel's maximum voltage with no load connected to it. It may sometimes also appear as Vca. If you measure with a voltmeter at the terminals of the panel in the sun and disconnected from the rest of the installation, this is the voltage you will get. Remember that when measuring you may get a slightly different value because you are not in laboratory conditions. It is measured in volts and is important information when specifying other components of the installation such as inverters, charge controllers, etc.

Short circuit current or Isc.

This is the current, measured in amperes, that the panel can generate when short-circuited. It can be measured directly at the terminals using an ammeter and joining the positive wire to the negative wire to cause the short circuit.

Shutterstock 59399170 1536x979

Maximum power voltage or Vmp.

This is the voltage the panel produces at maximum power, and it is the figure that determines whether the panel is a 12 V or 24 V panel (the most common types). Note that the datasheet will not show the 12 or 24 V values directly. The solar panel's voltage must be higher than the batteries' charging voltage (in off-grid installations), so a higher Vmp figure will appear. For example, for a 12 V panel the Vmp will be between 15 and 19, for a 24 V panel the Vmp will be between 36 and 39, etc.

Maximum power current or Imp.

This is the maximum current the solar panel produces when connected to the installation, in amperes. It is important that the installation's charge controller is able to handle the current stated here.

Other datasheet information.

In addition to the parameters we have covered, datasheets may include other kinds of information that vary by manufacturer, for example:

  • Measurement conditions. As we have said several times in this article, the theoretical parameters are calculated under special laboratory conditions, which are those indicated in the “All Values Measured at STC” section. These conditions are: 1000 W/m2 of irradiance, a cell temperature of 25 degrees Celsius and an AM spectral distribution of 1.5.
  • Maximum system voltage. This voltage determines the maximum overall voltage the panel is designed for. In other words, when it is installed alongside others in the installation, the total must not exceed this voltage.
  • Weight and dimensions. It is also common to see both the solar panel's weight in kilograms and its length and width in millimetres. Finally, other information also appears, such as the manufacturer's contact details, the various certificates it holds and other additional information.

Reading a solar panel datasheet.

Understanding a solar panel datasheet requires knowing certain electrical parameters. If in doubt, it is always a good idea to contact a solar energy expert company to resolve any doubts or problems that may arise when carrying out an installation.